Immersion Characteristic by Organic/Inorganic Hybrid Solution Coating of Austenite Stainless Steel Degraded in 480-720oC

K.W. Nam, Y. S. Kim, H. R. Jeong

Abstract


This study was conducted to investigate the pitting resistance due to degradation of stainless steel (STS310S, STS316L and STS347H). The three types of non-heat treated specimens did not exhibit pitting regardless of whether or not a coating had been applied. In an acidic solution, the non-coated specimen and the OIBD-2 coated specimen of degraded stainless steel had pitting, but the OIBD-1 coated specimen did not have it at all. In an alkaline solution, all of the degraded specimens did not exhibit pitting at all.

Keywords


Organic/Inorganic Hybrid Solution, Immersion, Salt Spray Test, Austenite Stainless, Degradation


DOI
10.12783/dteees/seeie2016/4676

Refbacks

  • There are currently no refbacks.