Fault Feature Extraction of Relay Valve Leakage Based on Test for Standard EMU Brake System

Jian-yong ZUO, Jing-xian DING, Shun PENG, Guo HU, Tie-feng ZHAO, Jia-liang LIU

Abstract


In order to excavate the leakage fault of the relay valve for the standard EMU brake system, a test using the fault injection method is carried out in this paper. By processing the pressure data collected by the pressure sensor, the BC steady-state pressure of the brake hold phase, determined as leakage fault feature, under the normal and leaking conditions is extracted and analyzed. The test results show that the BC steady-state pressure of the brake hold phase is the effective feature of the leakage fault of the relay valve, which provides a feasible way for the mining of the relay valve leakage fault.

Keywords


Standard EMU, Relay valve, Leakage, Feature extraction