Measurement of Foil Bonded Strain Gauges with 3 Wire Quarter Bridge

Hu HE, Guang-jun YI, Jian-hui SUN

Abstract


The change in resistance of the foil bonded strain gauge is small, resulting in a small change in the output from the sensor, so lead wire effects and electro-magnetic noise can compromise the measurement. To measure such small changes in resistance, this paper compared 3 Wire Quarter Bridge with 2 wire quarter bridge strain circuit, half bridge strain circuit and full bridge strain circuit, recommended using 3 wire quarter bridge to measure the resistance of foil bonded strain gauges. 3 wire quarter bridges are easier to install, reusable, have superior temperature compensation, and some are for dynamic monitoring.

Keywords


Foil bonded strain gauges, 3 Wire Quarter Bridge, Measurement circuit


DOI
10.12783/dtetr/ameme2016/5784

Refbacks

  • There are currently no refbacks.